An experimental setup for spectroscopy applications of optically generated VUV and XUV radiation

Year: 2002

Authors: Cavalieri S., Materazzi M., Eramo R.

Autors Affiliation: Dipartimento Di Fisica, European Laboratory for Non-Linear Spectroscopy (LENS), Università Di Firenze, Largo E. Fermi 2, I-50125 Firenze, Italy

Abstract: In this paper, we present an experimental setup to study photoionization of atoms and molecules using the high-order harmonic radiation generated by a highly non-linear process. We report on the characteristics of this table-top experimental apparatus showing also the results of the photoionization of krypton gas, by the use of the ninth order harmonic of fs Ti:S laser. observed both in the electron spectrum and in the mass spectrum, (C) 2002 Elsevier Science Ltd. All rights reserved.

Journal/Review: OPTICS AND LASERS IN ENGINEERING

Volume: 37 (5)      Pages from: 577  to: 583

More Information: We acknowledge the support of the European Community under contract ERB FMGE CT 950017. The valuable technical assistance of the mechanical and electronic services of Lens is greatly appreciated.
KeyWords: Atoms; Harmonic generation; Krypton; Molecules; Photoionization; Solid state lasers; Spectrum analysis; Ultraviolet spectroscopy, High order harmonic generation, Ultraviolet radiation
DOI: 10.1016/S0143-8166(01)00128-2

Citations: 1
data from “WEB OF SCIENCE” (of Thomson Reuters) are update at: 2024-11-17
References taken from IsiWeb of Knowledge: (subscribers only)