A new dynamic technique for the measurement of hemispherical total emittance
Year: 1992
Authors: Righini F., Bussolino GC., Rosso A.
Autors Affiliation: CNR, Inst Metrol G Colonnetti, I-10135 Turin, Italy
Abstract: A new dynamic technique for the measurement of thermal conductivity under development at the IMGC requires accurate values of heat capacity and of hemispherical total emittance at high temperature. Until recently, these data were provided by subsecond pulse heating experiments performed on the same specimens in the same apparatus. The pulse heating technique is the most accurate method for the determination of heat capacity at high temperatures, but because of various experimental problems, the accuracy of hemispherical total emittance determinations is limited to 5%. A new method for a more accurate determination of hemispherical total emittance is proposed, which uses the same experimental data available from thermal conductivity experiments. An analysis of the temperature profiles measured during the free cooling indicates that regions with high-temperature gradients (toward the ends of the specimen) are the best regions for thermal conductivity measurements, while regions with low-temperature gradients (at the center of the specimen) are the best regions for hemispherical total emittance determinations. The new measurement method and some preliminary results are presented and discussed.
Journal/Review: INTERNATIONAL JOURNAL OF THERMOPHYSICS
Volume: 13 (1) Pages from: 17 to: 27
KeyWords: dynamic measurements; emittance; high temperature; scanning pyrometry; niobiumDOI: 10.1007/BF00503352Citations: 3data from “WEB OF SCIENCE” (of Thomson Reuters) are update at: 2024-11-17References taken from IsiWeb of Knowledge: (subscribers only)Connecting to view paper tab on IsiWeb: Click hereConnecting to view citations from IsiWeb: Click here