Development of Ti/Au and Hf/Au thermometers for cryogenic detectors

Year: 2000

Authors: Barucci M., Gottardi E., Peroni I., Peruzzi A., Ventura G.

Autors Affiliation: Dipartimento di Fisica, Università di Firenze, via L. Pancaldo 3, 50127 Firenze, Italy; CNR-IMGC, Strada delle Cacce 73, 10139 Torino, Italy; NMi van Swinden Laboratorium, P.O. Box 654, 2600 AR Delft, Netherlands

Abstract: Transition Edge Sensors (TES) based on Ti/Au and Hf/Au bilayers are presented. By varying the relative thickness of the layers, we obtained transition temperatures of between 140 – 300 mK and 33 – 105 mK, respectively. Possible applications in the field of X-ray spectroscopy and particle detection are discussed.

Conference title:
Place:

KeyWords: Cryogenic equipment; Electron beams; Evaporators; Gold; Hafnium; Multilayers; Particle detectors; Sensors; Temperature; Titanium; X ray spectroscopy, Cryogenic detectors; Particle detection; Transition edge sensors, Thermometers