A strategy for the measurement of CO2 distribution in the stratosphere

Year: 2016

Authors: Carlotti M., Dinelli B. M., Innocenti G., Palchetti L.

Autors Affiliation: Univ Bologna, Dipartimento Chim Ind Toso Montanari, Bologna, Italy; CNR, ISAC, Bologna, Italy; CNR, INO, Sesto Fiorentino, FI, Italy.

Abstract: In this study we introduce a new strategy for the measurement of CO2 distribution in the stratosphere. The proposed experiment is based on an orbiting limb sounder that measures the atmospheric emission within both the thermal infrared (TIR) and far-infrared (FIR) regions. The idea is to exploit the contribution of the pure rotational transitions of molecular oxygen in the FIR to determine the atmospheric fields of temperature and pressure that are necessary to retrieve the distribution of CO2 from its rovibrational transitions in the TIR. The instrument envisaged to test the new strategy is a Fourier transform spectrometer with two output ports hosting a FIR detector devoted to measuring the O2 transitions and a TIR detector devoted to measure the CO2 transitions. Instrumental and observational parameters of the proposed experiment have been defined by exploiting the heritage of both previous studies and operational limb sounders. The performance of the experiment has been assessed with two-dimensional (2-D) retrievals on simulated observations along a full orbit. For this purpose, optimal spectral intervals have been defined using a validated selection algorithm. Both precision and spatial resolution of the obtained CO2 distributions have been taken into account in the results-evaluation process. We show that the O2 spectral features significantly contribute to the performance of CO2 retrievals and that the proposed experiment can determine 2-D distributions of the CO2 volume mixing ratio with precisions of the order of 1 ppmv in the 10-50 km altitude range. The error budget, estimated for the test case of an ideal instrument and neglecting the spectroscopic errors, indicates that, in the 10-50 km altitude range, the total error of the CO2 fields is set by the random component. This is also the case at higher altitudes, provided the retrieval system is able to model the non-local thermal equilibrium conditions of the atmosphere. The best performance is obtained at altitudes between 20 and 50 km, where the vertical resolution ranges from 3 to 5 km, and the horizontal resolution is of the order of 300-350 km depending on latitude.

Journal/Review: ATMOSPHERIC MEASUREMENT TECHNIQUES

Volume: 9 (12)      Pages from: 5853  to: 5867

More Information: The MWs selection task was carried out by exploiting an Erasmus+ Traineeship 2014/2015 grant at Oxford University, with the supervision of Anu Dudhia, whom we thank for his valuable contribution.
KeyWords: Algorithm; carbon dioxide; error analysis; FTIR spectroscopy; microwave limb sounder; mixing ratio; oxygen; spatial resolution; stratosphere
DOI: 10.5194/amt-9-5853-2016

Citations: 1
data from “WEB OF SCIENCE” (of Thomson Reuters) are update at: 2024-10-27
References taken from IsiWeb of Knowledge: (subscribers only)
Connecting to view paper tab on IsiWeb: Click here
Connecting to view citations from IsiWeb: Click here