Experimental results on a Mg atomic beam

Anno: 1985

Autori: Godone A., Bava E., De Marchi A., Rovera G.D., Giusfredi G.

Affiliazione autori: Istituto Elettrotecnico Nazionale (IEN) “G. Ferraris”
Istituto Nazionale di Ottica (INO)

Abstract: Recent advances in the realization of a frequency standard based on the fine structure transition 3P13P0 of 24Mg are reported. With the frequency stability obtained in the present setup, the zero-field transition frequency is evaluated to be 601 277 158.33 ± 0.2 kHz. The feasibility of a frequency standard with an ultimate uncertainty of 10-13 in a measurement time of less than 10 s is discussed.

Giornale/Rivista: IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT

Volume: IM-34 (2)      Da Pagina: 129  A: 132

Parole chiavi: Magnesium; Atomic Clock;
DOI: 10.1109/TIM.1985.4315285

Citazioni: 6
dati da “WEB OF SCIENCE” (of Thomson Reuters) aggiornati al: 2024-04-28
Riferimenti tratti da Isi Web of Knowledge: (solo abbonati)
Link per visualizzare la scheda su IsiWeb: Clicca qui
Link per visualizzare la citazioni su IsiWeb: Clicca qui