Auto-prepulse operation of a long-pulse XeCl laser

Anno: 1992

Autori: Franceschini M.A., Pini R., Salimbeni R., Vannini M.

Affiliazione autori: Istituto di Elettronica Quantistica del C.N.R., Via Panciatichi 56/30, Florence, I-50127, Italy

Abstract: A standard corona preionized XeCl laser prototype has been excited by a very simple L-C circuit consisting of a large storage capacitance charged at relatively low voltage (12 kV) and discharged via a switch on the electrodes, tightly coupled with the peaking capacitors. The resulting overvoltage following the switch closure behaves as an effective and automatic prepulse, providing a homogeneous discharge lasting up to 400 ns. Energy output levels of the order of 150 mJ at 1.4% overall efficiency have been achieved.

Giornale/Rivista: APPLIED PHYSICS B PHOTOPHYSICS AND LASER CHEMISTRY

Volume: 54 (4)      Da Pagina: 259  A: 264

Parole chiavi: DISCHARGE STABILITY; RADIATION
DOI: 10.1007/BF00325190

Citazioni: 7
dati da “WEB OF SCIENCE” (of Thomson Reuters) aggiornati al: 2024-05-12
Riferimenti tratti da Isi Web of Knowledge: (solo abbonati)
Link per visualizzare la scheda su IsiWeb: Clicca qui