The calorimeter system of the new muon g-2 experiment at Fermilab
Anno: 2016
Autori: Alonzi L.P., Anastasi A., Bjorkquist R., Cauz D., Cantatore G., Dabagov S., Di Sciascio G., Di Stefano R., Fatemi R., Ferrari C., Fienberg A.T., Fioretti A., Frankenthal A., Gabbanini C., Gibbons L.K., Giovanetti K., Goadhouse S.D., Gohn W.P., Gorringe T.P., Hampai D., Hertzog D.W., Iacovacci M., Kammel P., Karuza M., Kaspar J., Kiburg B., Li L., Marignetti F., Mastroianni S., Moricciani D., Pauletta G., Peterson D.A., Pocanic D., Santi L., Smith M.W., Sweigart D.A., Tishchenko V., Van Wechelm T.D., Venanzoni G., Wall K.B., Winter P., Yai K.
Affiliazione autori: Università di Cassino, Cassino, Italy; University of Virginia, Charlottesville, VA22904, USA; Laboratori Nazionali Frascati dell\’INFN, Frascati, Italy; James Madison University, Harrisonburg, VA22807, USA; Cornell University, Ithaca, NY14850, USA; University of Kentucky, Lexington, KY40506, USA; Dipartimento di Fisica e di Scienze della Terra dell\’Università di Messina, Messina, Italy; Università di Napoli, Napoli, Italy; INFN, Sezione di Napoli, Napoli, Italy; Osaka University Graduate School of Science, Osaka, Japan; Istituto Nazionale di Ottica del C.N.R., UOS Pisa, Pisa, Italy; INFN Sezione di Roma Tor Vergata, Roma, Italy; University of Washington, Box 351560, Seattle, WA98195, USA; Shanghai Jiao Tong University, Shanghai, China; Shanghai Key Laboratory for Particle Physics and Cosmology, Shanghai, China; Università di Udine, Udine, Italy; Università di Trieste, Trieste, Italy; INFN, Sezione di Trieste e G.C. di Udine, Trieste, Italy; University of Rijeka, Rijeka, Croatia; University of Virginia, Charlottesville, VA 22903 USA; Fermilab Natl Accelerator Lab, Batavia, IL 60510 USA; Brookhaven Natl Lab, Upton, NY 11973 USA; Argonne Natl Lab, Argonne, IL 60439 USA
Abstract: The electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF 2 Cerenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here the requirements for this system, the achieved solution and the results obtained from a test beam using 2.0-4.5 GeV electrons with a 28-element prototype array.
Giornale/Rivista: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
Volume: 824 Da Pagina: 718 A: 720
Maggiori informazioni: National Science Foundation (NSF); NSF – Directorate for Mathematical & Physical Sciences (MPS): 1337542, 1307328, 1614839Parole chiavi: Lead–fluoride crystals; Silicon photomultiplier; Electromagnetic calorimeterDOI: 10.1016/j.nima.2015.11.041Citazioni: 5dati da “WEB OF SCIENCE” (of Thomson Reuters) aggiornati al: 2024-04-21Riferimenti tratti da Isi Web of Knowledge: (solo abbonati) Link per visualizzare la scheda su IsiWeb: Clicca quiLink per visualizzare la citazioni su IsiWeb: Clicca qui